Could not read the WMI value (NT code 0x80041010)
Hi, I'm getting this error when I bind the WMITerminalServer Template to my organiser to view Terminal sessions performance information. Could not read the WMI value (NT code 0x80041010). Check your...
View Articlezenwin "NT_STATUS_NET_WRITE_FAULT" with restricted
Hi,We are trying to setup a wmi restricted account for zenwin and zeneventlog. Using wmic, it's working fine, but from Zenwin it broke, complaining both about "NT_STATUS_NET_WRITE_FAULT" and...
View ArticleHOW TO CONFIGURE WMI ACCESS ON WINDOWS FOR A NON ADMIN USER
Hi,If you, like me have to configure WMI access on Windows servers for a non admin user in order for Zenoss to read the eventlog etc, read on...IntroductionZenoss is able to read & query Windows...
View ArticleWMI NT code 0xc002001b, alerts for "Could not read Windows services" then clears
ZenossZenoss 3.1.0OSLinux (x86_64) 2.6.18 (Linux hz1.uapps.net 2.6.18-238.9.1.el5 #1 SMP Tue Apr 12 18:10:13 EDT 2011 x86_64)ZopeZope 2.12.1PythonPython 2.6.2DatabaseMySQL 5.0.77 (Ver 5.0.77)RRDRRDtool...
View ArticleWMI Non-Admin user not seeing all services
Hi, I have gone through all the steps to set up a non-admin user for monitoring (DCOM, WMI, enable ntlm2 etc). All LOOKS good, except the zenoss user does not see all the services. I have not found any...
View ArticleUnable to connect to WMI issue
Hi, all ... I've been unable to connect via WMI to any of our Windows servers. They're all VMs, running 2008R2. I've gone through all of the postings and guides I can find here on the site, with no...
View ArticleMonitor windows file system with a twist
To start with my exchagne servers all run on Xensource so the server I talk about below is really virtual but, Zenoss should not be concerned with that.I have a 64 bit Windows 2003 server that has one...
View ArticleGraphs are empty and have "nan" for values
I'm pretty new to Zenoss and could use any advice on the following issue. We are running Zenoss v3.0-v03 monitoring Windows Servers. One server in particular has 3 graphs that are blank and the values...
View ArticleZenoss for windows
Hi Guys, I'm a total beginner on this so apologies in advance if my question has already been asked . I'm looking to install this on my windows server 2008 serevrs , I have 8 in the same lan and want...
View ArticleProblems with Windows Server 2012
Hi all, I am using the latest Zenoss 4.2.4 which includes WMI version 1.3.15 (from the Advanced | Versions page). I have absolutely no issues using WMI to monitor my Windows 2003, 2008, and 2008 R2...
View Article